21.3" Monochrome LCD Monitor
3 megapixel high-resolution diagnostic monochrome monitor ideal for displaying an entire chest CR image. High-definition and multifunctional model featuring precise calibration compliant with the DICOM Part 14 standard.
  • Contact EIZO
2 items
 
  • Features
  • Specifications
  • Documents Compatibility
  • Graphics Boards
  • QC Software & Tools Accessories

Making Each Life Visual



Environmentally-Friendly LED Backlight

Longer Service Life with LED BacklightBy utilizing an energy-efficient LED as a backlight, the monitor achieves a high-brightness and low power consumption at the same time. Unlike conventional CCFL backlights, LED backlights deteriorate more slowly and thus the monitor offers a longer service life. Since the LED backlight is mercury free, it will reduce any potential impact on the environment when it is disposed of.

Consistency with DICOM Part 14 Calibration

With the bundled RadiCS LE quality control software, a simplified calibration compliant with the DICOM Part 14 standard can be performed to correct the brightness and grayscale tones of the monitor ensuring the most accurate and consistent shadings possible over time.

Easy Calibration with Integrated Front Sensor

An Integrated Front Sensor (IFS) housed within the front bezel measures brightness and grayscale tones and calibrates to the DICOM Part 14 standard. Without having to connect and disconnect, an IFS performs QC tasks and does not interfere with the viewing area. This dramatically cuts monitor quality control workload and maintenance costs.

ifs_en.jpg

Brightness Uniformity for a Steadier Image Across the Screen

The Digital Uniformity Equalizer (DUE) function provides optimum brightness uniformity which is difficult to attain due to the characteristics of LCD monitors.

Quick Brightness Stabilization for Instant Viewing

At startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level. In addition, a sensor measures the backlight brightness and compensates for brightness fluctuations caused by the ambient temperature and the passage of time.

Customer Assurance with Medical Standards

Meets the strictest medical, safety, and EMC emission standards.

Warranty with Safety and Trust

EIZO and its authorized distributors offer a five-year full warranty.

Displaying with Separate Brightness Levels

For monochrome monitors, Hybrid Gamma function automatically distinguishes the medical images from the non-medical areas such as the tool palettes and displays each one at its optimum brightness. Decreasing the tool palette area's brightness leads to less eye fatigue.

Accuracy in distinction may depend on how images are aligned.

Viewer software compatibility verification is required.

Diagnostic Precision with DICOM Part 14 Factory Adjustment

To ensure the most accurate and consistent shadings possible, EIZO carefully measures and sets every grayscale tones on the production line to produce a monitor compliant with DICOM Part 14.

Presence Sensor for Power Savings

The presence sensor feature unites convenience with savings by ensuring that the monitor conserves power when it is not in use. The presence sensor prompts the monitor to switch to power save mode when it detects the user is away from the monitor, and then resume normal operation when the user returns.

10-Bit Simultaneous Grayscale Display

10-bit (1,024 tones) simultaneous grayscale display extends grayscale fidelity to the boundaries of human visual perception abilities and helps radiologists discern the finest nuances within an image.

10-bit graphics board and 10-bit viewer software needed for 10-bit display.

Mode Selection for Optimum Viewing

Selectable with the front panel buttons, the CAL Switch function allows for various imaging modes of different modalities such as CR, CT, and endoscope images. Furthermore, auto mode settings can be made with the Auto CAL Switch function.

Wide Viewing Angles for Multiple People Use

Wide Viewing angles with minimal color shift when viewed from the side.

Brightness Stability Within Usage Time Guaranteed

EIZO's confidence in its product quality extends to brightness stability which is also covered during the usage time specified in the warranty.

Versatile Positioning for Improved Operability

EIZO's highly versatile stand offers tilt, swivel and a wide height adjustment range enabling you to use the monitor with greater comfort.

 

Our Contribution to SDGs

As part of its sustainability initiatives, EIZO is contributing towards the United Nations' Sustainable Development Goals (SDGs).   SDGs Logo

Supporting a Healthy Life
Starting with our message “Making Each Life Visual”, we aim to support optimal medical care for each and every individual through accurate diagnosis and treatment afforded by our innovative healthcare technologies.
 
SDGs 03SDGs 08
     
Environmentally Conscious
Our healthcare products are designed to promote energy efficiency for reduced power consumption and greenhouse gas emissions, while maintaining the high performance and functionality needed in healthcare. We also implement a responsible after-service recycling system.
 
SDGs 07SDGs 12
Model Variations GX340-CL-BK: Clear Base, with stand, black
GX340-CL-P-BK: Pairing, with stand, black
Panel  
Type Monochrome (IPS)
Backlight LED
Size 21.3" (54 cm)
Native Resolution 1536 x 2048 (3:4 aspect ratio)
Viewable Image Size (H x V) 324.8 x 433.1 mm
Pixel Pitch (H x V) 0.2115 x 0.2115 mm
Grayscale Tones 10-bit (DisplayPort): 1,024 from a palette of 16,369 (14-bit) tones
8-bit: 256 from a palette of 16,369 (14-bit) tones
Viewing Angles (H / V, typical) 176° / 176°
Brightness (typical) 1200 cd/m2
Recommended Brightness for Calibration 500 cd/m2
Contrast Ratio (typical) 1400:1
Response Time (typical) 40 ms (black-white-black)
Video Signals  
Input Terminals DisplayPort, DVI-D (dual link)
Digital Scanning Frequency (H / V) 31 - 127 kHz / 29 - 61.5 Hz
USB  
Upstream USB 2.0: Type-B
Downstream USB 2.0: Type-A x 2
Power  
Power Input AC 100 - 120 V, 200 - 240 V: 50 / 60 Hz
Typical Power Consumption 36 W
Maximum Power Consumption 90 W
Power Save Mode 1.6 W or less
Sensor Backlight Sensor, Integrated Front Sensor, Presence Sensor, Ambient Light Sensor
Features & Functions  
Brightness Stabilization Yes
Digital Uniformity Equalizer Yes
Preset Modes CAL Switch (DICOM, CAL1, CAL2, Hybrid-γ)
OSD Languages English, German, French, Italian, Japanese, Simplified Chinese, Spanish, Swedish, Traditional Chinese
Physical Specifications  
Net Weight 10.2 kg
Net Weight (Without Stand) 7.5 kg
Hole Spacing (VESA Standard) 100 x 100 mm
Certifications & Standards (Please contact EIZO for the latest information.) CE (Medical Device), EN60601-1, ANSI/AAMI ES60601-1, CAN/CSA-C22.2 No. 60601-1, IEC60601-1, VCCI-B, FCC-B, CAN ICES-3 (B), RCM, RoHS, China RoHS, WEEE, CCC, EAC
FDA 510(k) Clearance for General Radiography
Dedicated Software  
Monitor Quality Control Software RadiCS Supported
Supplied Accessories (May vary by country. Please contact EIZO for details.)  
Signal Cables Dual Link DVI-D (3 m), DisplayPort (3 m)
Others AC power cord (3 m), USB Type-A - USB Type-B cable (3 m), Utility Disk (RadiCS LE, ScreenManager Pro for Medical, user's manual)
Warranty 5 Years
Dimension Drawing GIF

Brochures

RadiForce general
14.4 MB

Download

 

Manuals

Languages

RadiForce GX240 / GX340 Instructions for Use_UsersManual English 1.52 MB PDF
RadiForce GX240 / GX340 Instructions for Use_UsersManual German 1.77 MB PDF
RadiForce GX240 / GX340 Instructions for Use_UsersManual French 1.76 MB PDF
RadiForce GX240 / GX340 Instructions for Use_UsersManual Russian 1.74 MB PDF
RadiForce GX240 / GX340 Instructions for Use_UsersManual Chinese-Simplified 1.98 MB PDF
GX340 / GX240 / RX340 / RX240 / Instructions for Use_SetupManual English
German
French
Chinese-Simplified
3.34 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Russian) Russian 1.37 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Italiano) Italian 1.35 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Czech) Czech 1.36 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Svenska) Swedish 1.35 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Chinese-Traditional) Chinese-Traditional 1.53 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Arabic) Arabic 1.59 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Danish) Danish 1.36 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Dutch) Dutch 1.35 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Finnish) Finnish 1.35 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Greek) Greek 1.37 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Korean) Korean 1.46 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Norwegian) Norwegian 1.36 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Polish) Polish 1.36 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Portuguese) Portuguese 1.36 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Espanol) Spanish 1.36 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Turkish) Turkish 1.35 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Hungarian) Hungarian 1.03 MB PDF
RadiForce RX240 / RX340 / GX240 / GX340 Setup manual (Croatian) Croatian 1.02e+3 KB PDF
ScreenSlicer Ver.1.1.5 Software manual (English) English 1.88 MB PDF

Compatibility

Date Subject
October 30, 2023 HP Z6 G5 Workstation and FlexScan, RadiForce Compatibility
August 3, 2023 HP Z4 G5 Workstation and FlexScan, RadiForce Compatibility
November 1, 2022 HP Z2 SFF G9, Z2 Tower G9, Z2 Mini G9 Workstation and FlexScan, RadiForce Compatibility
February 1, 2022 HP Z2 SFF G5, Z2 Tower G5, Z2 G8 Tower Workstation and FlexScan, RadiForce Compatibility
June 24, 2021 Dell Precision 5820 Tower and RadiForce Compatibility
March 11, 2021 HP Z2 Mini G5, Z2 G5 SFF, Z2 Tower G5 Workstation and FlexScan, RadiForce Compatibility
April 14, 2020 Lenovo ThinkStation P330 SFF, P330 Tiny, P520c, ThinkPad P53, P53 (Thunderbolt 3 Dock) and FlexScan, RadiForce Compatibility
July 30, 2019 Abnormal Display Issue on Microsoft Windows 10 May 2019 Update (1903)
January 23, 2019 A USB signal transmission error may occur between some PCs and EIZO monitors when using EIZO software.
November 29, 2018 HP Z2 Mini G4 Workstation and RadiForce Compatibility
November 15, 2018 HP Z2 Tower G4, Z2 SFF G4 Workstation and RadiForce Compatibility
September 20, 2018 DELL T5820, T7820 and RadiForce Compatibility
March 15, 2018 HP Z240SFF, Z240, Z4 G4, Z6 G4, Z8 G4 Workstation and RadiForce Compatibility
April 27, 2016 Compatibility with Hewlett-Packard Z240SFF/Z240/Z440/Z640/Z840 (2016/4)
July 10, 2015 Compatibility between EIZO RadiForce Monitors and Hewlett-Packard Z230SFF/Z230/Z440/Z640/Z840

Technical Information

November 14, 2012 The Advantages of Medical LCD Monitors with LED Backlights [PDF]

This document explains the three advantages of medical image display monitors that utilize an LED backlight.

Graphics Boards
MED-XN83

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN63

- EIZO original driver and bios
- Daisy chain supported

Recommended
Graphics Boards
MED-XN43

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN51LP

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN31LP

- EIZO original driver and bios
- Daisy chain supported

Graphics Boards
MED-XN72

- EIZO original driver and bios
- Daisy chain supported

Recommended
Quality Control Software & Tools
RadiCS UX2

- Quality Control Software
- UX2 Calibration Sensor bundled

Quality Control Software & Tools
UX2 Sensor

- Quality Control External Calibration Sensor

Comfort Light for Reading Rooms
RadiLight

- Comfort Light for Reading Rooms

Arms
LA-011-W

35° up tilt and 180° swivel wide adjustment range

Panel Protector
RP-913

- Protect against dust and scratches
- Fit between screen and bezel
- Integrated Front Sensor usable

Monitor Cleaning Kit
ScreenCleaner

- Keep your screen free from dust and fingerprints
- Includes pump spray and cloth

 

  • Making Each Life Visual
  • Creating a Comfortable Reading Environment for Doctors
  • Choosing the Ideal Monitor for Teleradiology
  • RX1270 Case Study for Multi-Modality
  • RX1270 Case Study for Mammography
  • EIZO-Sponsored Seminars Supporting Early Detection of Breast Cancer
  • QC Standards for Medical Monitors
prev next